RELIABILITY ENHANCEMENT OF ACF JOINED FLIP CHIPS WITH PARYLENE C AS A PROTECTIVE COATING

Kati H. Kokko, Milad Mostofizadeh, Donald W. Lupo

References

  1. [1] M.R. Neuman, G.D. Baura, S. Meldrum, O. Soykan,M.E. Valentinuzzi, R.S. Leder, S. Micera & Y-T. Zhang,Advances in medical devices and medical electronics,Proceedings of the IEEE, 100, 2012, 1537-1550.
  2. [2] D.D. Zhou, R.J. Greenberg, Microsensors andmicrobiosensors for retinal implants, Frontiers inBioscience, 10(1), 2005, 166-179.
  3. [3] G. Mian, G. Newaz, L. Vendra, N. Rahman, D.G.Georgiev, G. Auner, R. Witte & H. Herfurth, Laserbonded microjoints between titanium and polyimide forapplications in medical implants, Journal of MaterialsScience: Materials in Medicine, 16(3), 2005, 229-237.
  4. [4] M. Kazemi, E. Basham, M. Sivaprakasam, G. Wang,D. Rodger, J. Weiland, Y.C. Tai, W. Liu & M. Humayun,A test microchip for evaluation of hermetic packagingtechnology for biomedical prosthetic implants, Proc. 26thAnnual International Conf. of the IEEE EMBS, SanFransisco, CA, 2004, 4093-4095.
  5. [5] N. Amanat, N.L. James & D.R. McKenzie, Weldingmethods for joining thermoplastic polymers for thehermetic enclosure of medical devices, MedicalEngineering & Physics, 32(7), 2010, 690-699.
  6. [6] J.J. Licari, Coating materials for electronicapplications; polymers, processes, reliability, testing(William Andrew Publishing, Inc.: New York, 2003).
  7. [7] H-M. Tong, L.S. Mok, K.R. Grebe, H.L. Yeh, K.K.Srivastava & J.T. Coffin, Effects of parylene coating onthe thermal fatigue life of solder joints in ceramicpackages, IEEE Transactions on Components, Hybrids,and Manufacturing Technology, 16 (5), 1993, 571-576.
  8. [8] D. Rodger, A. Fong, W. Li, H. Ameri, A. Ahuja, C.Gurtierrez, I. Lavrov, H. Zhong, P. Menon, E. Meng, J.Burdick, R. Roy, R. Edgerton, J. Weiland, M. Humayun& Y-C. Tai, Flexible parylene-based multielectrode arraytechnology for high-density neural stimulation andrecording, Sensors and Actuators B, 132 (2), 2008, 449-460.
  9. [9] S. Vaddiraju, I. Tomazos, D.J. Burgess, F.C. Jain & F.Papadimitrakopoulos, Emerging synergy betweennanotechnology and implantable biosensors: A review,Biosensors and Bioelectronics, 25(7), 2010, 1553-1565.
  10. [10] J. Govaerts, W. Cristiaens, E. Bosman & J.Vanfleten, Fabrication process for embedding thin chipsin flat flexible substrates, IEEE Transactions onAdvanced Packaging, 32(1), 2009, 77-83.
  11. [11]Jedec Standard, Steady State Temperature HumidityBias Life Test, EIA/JESD22-A101-B, (ElectronicIndustries Association, 1997).
  12. [12] Y.C. Lin, J. Zhong, A review of the influencingfactors on anisotropic conductive adhesive joiningtechnology in electrical applications, Journal of MaterialScience, 43(9), 2008, 3072-3093.
  13. [13] X.J. Fan, S.W.R. Lee & Q. Han, Experimentalinvestigations and model study of moisture behaviors inpolymeric materials, Microelectronics Reliability, 49(8),2009, 861-871.
  14. [14] X.Q. Shi, Y.L. Zhang, W. Zhou & X.J. Fan, Effect ofhygrothermal aging on interfacial reliability ofsilicon/unferfill/FR-4 assembly, IEEE Transactions onComponents and Packaging Technologies, 31(1), 2008,94-103.
  15. [15] L.L. Mercado, J. White, V. Sarihan & T-Y. Lee,Failure mechanism study of anisotropic conductive film(ACF) packages, IEEE Transactions on Components andPackaging technologies, 26 (3), 2003, 509-516.

Important Links:

Go Back