EXPERIENCE WITH OFF-LINE PARTIAL DISCHARGE DIAGNOSTIC TESTING ON 3.2-kV, 6.6-kV, AND 11.5-kV RATED MOTORS

Evgeni Volpov and Anatoly Shkolnik

References

  1. [1] R. Engelmann and W. Middendorf, Handbook of ElectricMotors, By M. Dekker, Inc. NY, USA, 1995, 448–454.
  2. [2] W. Hutter and R. Schuler, Rotating Electrical Machines,Winding Diagnostic and Monitoring Methods, ABB DrivesAG, 1996.
  3. [3] G. Stone, The use of Partial Discharge measurements to assess the condition of Rotating Machine Insulation. IEEE Electrical Insulation Magazine, 1996, 12(4), 23–27.
  4. [4] G. Rabach and M. Visintin, On the interpretation of PDpatterns detected at Motor terminals, CIGRE-2000, paper11-304, Paris, 2000.
  5. [5] E. Binder, A. Draxler, H. Egger, A. Hummer, and H.R. Fuchs, Developments and verification tests of diagnostics methods for hydro-generators CIGRE-2000, paper 11-301, Paris, 2000.
  6. [6] B. Fruth and D. Gross, Partial discharge signal generation,transmission and acquisition, IEE Proceedings –Science Mea-surement and Technology, 142(1), 1995, 22–28, www.pdix.com.
  7. [7] G. Liptak, J. Ruhe, and R. Schriler, Estimating the life of stator windings in rotating electrical machines, Int. Conf. the Evaluation and Modern Aspects of Synchronous Machines, Zurich, 1991.
  8. [8] G.C. Stone, Difficulties with calibrating partial discharge mea-surements on stator windings, IEEE Electrical Insulation Mag-azine, 1998, 9–12.
  9. [9] S. T´etreault, Experience with on-line PD testing on 4 kVmotors, Iris Rotating Machine Conference, 10–13 March 1998,Dallas, USA.
  10. [10] S. Tetrault, G.C. Stone, and H.G. Sedding, Monitoring partialdischarges on 4 kV motor windings, Copyright Material IEEEPCIC-97-16, Philadelphia, 16 September 1997.
  11. [11] H. Zhu, V. Green, M. Sasic, and S. Hariburton, On-line PDtesting on lower voltage rotating machines using high sensitivitycapacitors, CIGRE-2000, paper 11-204, Paris, 2000.
  12. [12] Tettex 2818/5283, Measuring and diagnostic equipment, In-struction Manual, www.haefely.com.184
  13. [13] IEC Std. IEC/TS 60034-27, Rotating electrical machines –Part 27: Off-line partial discharge measurements on the statorwinding insulation of rotating electrical machines, Ed. 1.0.2006.
  14. [14] IEEE Std. 1434-2000, IEEE trial-use guide to the measurementof partial discharges in rotating machinery, Published 16 August2000.
  15. [15] A. Shkolnik, The diagnostic methods for stator insulation ofhigh voltage rotating machines, CIGRE A1&D1 Joint Collo-quium, 24 October 2007.

Important Links:

Go Back