M. Gilany, E.S.T. Eldin, and D.K. Ibrahim
[1] M. Kezunovic & B. Perunicic, Fault location, Wiley Encyclo-pedia of Electrical and Electronics Engineering, Vol. 7 (JohnWiley & Sons, 1999), 276–285. [2] C.M. Wiggins, D.E. Thomas, T.M. Salas, F.S. Nickel, & H.W.Ng, A novel concept for URD cable fault location, IEEETransactions on Power Delivery, 9(1), January 1995, 591–597. doi:10.1109/61.277733 [3] S. Potivejkul, P. Kerdonfag, S. Jamnian, & V. KinnaresN,Design of a low voltage cable fault detector, Power EngineeringSociety Winter Meeting, 2000, IEEE, 1, 2000, 724–729. [4] Z.Q. Bo, R.K. Aggarwal, & A.T. Johns, A very accurate faultlocation and protection scheme for power cable using faultgenerated high frequency voltage transients, Proceedings ofthe 8th Electro-technical Conference, Industrial Applicationsin Power Systems, MELECON 96, Bari, Italy, May 1996,777–780. [5] E.M.T. Eldin, M.I. Gilany, M.M.A. Aziz, & D.K. Ibrahim, Awavelet-based fault location technique for aged power cablelines, Proceeding of the IEEE Power Engineering Society 2005General Meeting, Vol. 3, San Francisco, California, USA, 12–16June 2005, 2485–2491. [6] C.H. Kim, Y.B. Lim, W.G. Chung, T.W. Kwon, J.Y. Hwang,& I.D. Kim, A study on fault identification of undergroundcable using neural networks, IEEE Catalogue No. 95TH8130,1995, 571–576. [7] M.T. Glinkowski & N.C. Wang, ANNs pinpoint undergrounddistribution faults, IEEE Computers Applications in Power,October 1995, 31–34. doi:10.1109/67.468291 [8] K. Amano, H. Kon, & Y. Kumada, Fault location system forpower cable using global positioning system – fLAG –, FujikuraTechnical Review No. 31, January 2002. [9] C.M. Wiggins, D.E. Thomas, T.M. Salas, F.S. Nickel, & H.W.Ng, On-line fault location system for 66 kV underground cableswith fast O/E and A/D technique, IEEE Transactions onPower Delivery, 9(1), January 1994, 579–584. doi:10.1109/61.277733 [10] O.L. Willis, A review of fault locating techniques in medium-voltage power cable, Petroleum and Chemical Industry Con-ference, 1991, Industry Applications Society 38th Annual, 9–11September 1991, copyright material IEEE Paper No. PCIC-91-36, 225–228. [11] V. Maslov, Moisture and water resistance of electrical insulation(Moscow: MIR Publishers, 1975). [12] F.M. Clark, Insulating materials for design and engineeringpractice (London: John Wiley and Sons, Inc., 1962). [13] H. Lother, Power cables and their applications (Berlin andMucher: Siemens Aktiengesellschaft, 1979). [14] E.H. Shehab-Eldin & P.G. Mclaren, Travelling wave distanceprotection – problem areas and solutions, IEEE Transactionson Power Delivery, 3(3), July 1988, 894–902. doi:10.1109/61.193866 [15] M.S. Sachdev (Coordinator), et al., Advancements in micropro-cessor based protection and communication, IEEE Power Engi-neering Society, Piscataway, NJ, Tutorial Text No. 97TP120-0. [16] A. Phadke, M. Kezunovic, & B. Pickett, Synchronized samplingand phasor measurements for relaying and control, IEEETransactions on Power Delivery, 9(1), January 1994, 442–452. doi:10.1109/61.277716 [17] IEEE Standard for Synchrophasors, IEEE Standard, 1344–1995. [18] T. Mitsui, K. Hosoe, H. Usami, & S. Miyamoto, Developmentof fiber-optic voltage sensors and magnetic field sensors, IEEETransactions on Power Delivery, 4, October 1989, 2005–2011. doi:10.1109/61.35624 [19] L.S. Martine, J.F. Martins, & V. Fernao Pires, The applicationof neural networks and Clarke – Concordia transformation infault location in distribution power systems, IEEE/PES T&DTransmission and Distribution 2002 Asia Pacific, October2002, 2091–2095. [20] A.T. Johns & S.K. Salman, Digital protection for power systems(Peter Peregrinus Ltd, 1997), ISBN: 0863411959. [21] I. Daubechies, Ten lectures on wavelets, SIAM Society forIndustrial and Applied Mathematics, Philadelphia, 1992. [22] W. Chen, O.P. Malik, X. Yin, D. Chen, & Z. Zhang, Studyof wavelet-based ultra high speed directional transmissionline protection, IEEE Transactions on Power Delivery, 18(4),October 2003, 1134–1139. doi:10.1109/TPWRD.2003.817511 [23] MATLAB user’s guide, The Math Works Inc., Natick, MA. [24] Alternative Transient Program, Rule Book, 1987.
Important Links:
Go Back