A Survey of Techniques for Power Quality Monitoring

T. Lin, A. Domijan, Jr., and F. Chu

References

  1. [1] W.E. Reid, Power quality issues: Standards and guidelines,IEEE Trans. on Industry Applications, 32 (3), 1996, 625–632. doi:10.1109/28.502175
  2. [2] T.S. Sidhu & M.S. Sachdev, An iterative technique for fastand accurate measurement of power system frequency, IEEETrans. on Power Delivery, 13 (1), 1998, 109–115. doi:10.1109/61.660863
  3. [3] J.A. de la O, H.J. Altuve, & I. Diaz, A new digital filter forphasor computation, Part 1: Theory, IEEE Trans. on PowerSystems, 13 (3), 1998, 1026–1031. doi:10.1109/59.709093
  4. [4] J.A. de la O, H.J. Altuve, & I. Diaz, A new digital filterfor phasor computation, Part 2: Evaluation, IEEE Trans. onPower Systems, 13 (3), 1998, 1032–1037. doi:10.1109/59.709094
  5. [5] Y.H. Gu & M.H.J. Bollen, Time-frequency and time scaledomain analysis of voltage disturbances, IEEE Trans. on PowerDelivery, 15 (4), 2000, 1279–1283. doi:10.1109/61.891515
  6. [6] C.S. Moo, Y.N. Chang, & P.K. Mok, A digital measurementscheme for time varying transient harmonics, IEEE Trans. onPower Delivery, 10 (2), 1995, 588–593. doi:10.1109/61.400874
  7. [7] J. Ruiz, J. Ortuondo, N. Palacios, & J. Amantegui, Realtime power supply quality measurement and monitoring multi-channel system, IEEE Trans. on Power Delivery, 10 (3), 1995,1190–1199.171 doi:10.1109/61.400896
  8. [8] G.T. Heydt, C.C. Liu, L. Tu, & G. Hensley, Applications ofthe windowed FFT to electric power quality assessment, IEEETrans. on Power Delivery, 14 (4), 1999, 1411–1416. doi:10.1109/61.796235
  9. [9] S.J. Huang, C.L. Huang, & C.T. Hsieh, Application of GA-BOR transform technique to supervise power system tran-sient harmonics, IEE Proc. on Generation, Transmission &Distribution, 143 (5), 1996, 461–466. doi:10.1049/ip-gtd:19960534
  10. [10] P. Oshea, The use of sliding spectral windows for the parameterestimation in power system disturbance monitoring, IEEETrans. on Power Systems, 15 (4), 2000, 1261–1267. doi:10.1109/59.898099
  11. [11] F. Zhang, Z. Geng, & W. Yuan, The algorithm of interpolatingwindowed FFT for harmonic analysis of electric power system,IEEE Trans. on Power Delivery, 16 (2), 2001, 160–164. doi:10.1109/61.915476
  12. [12] T. Tsao, R. Wu, & C. Ning, The optimization of spectralanalysis for signal harmonics, IEEE Trans. on Power Delivery,16 (2), 2001, 149–153. doi:10.1109/61.915474
  13. [13] O. Chaari, P. Bastard, & M. Meunier, Prony’s method: Anefficient tool for the analysis of earth fault currents in Petersen-coil-protected networks, IEEE Trans. on Power Delivery,10 (3), 1995, 1234–1241. doi:10.1109/61.400901
  14. [14] D.J. Trudnowski, J.M. Johnson, & J.F. Hauer, Making Pronyanalysis more accurate using multiple signals, IEEE Trans. onPower Systems, 14 (1), 1999, 226–231. doi:10.1109/59.744537
  15. [15] A.A. Girgis, W.B. Chang, & E.B. Makram, A digital recursivemeasurement scheme for on-line tracking of power systemharmonics, IEEE Trans. on Power Delivery, 6 (3), 1991, 1153–1160. doi:10.1109/61.85861
  16. [16] G. Benmouyal, Frequency domain characterization of Kalmanfilters as applied to power system protection, IEEE Trans. onPower Delivery, 7 (3), 1992, 1129–1137. doi:10.1109/61.141823
  17. [17] I. Kamwa, R. Grondin, & D. Macnabb, On-line tracking ofchanging harmonics in stressed power systems: Applicationto Hydro-Quebec network, IEEE Trans. on Power Delivery,11 (4), 1996, 2020–2027. doi:10.1109/61.544290
  18. [18] M. Bettayeb & U. Qidwai, Recursive estimation of powersystem harmonics, Electric Power Systems Research, 47 (2),1998, 143–152. doi:10.1016/S0378-7796(98)00063-7
  19. [19] P.K. Dash, D.P. Swain, A.C. Liew, & S. Rahman, An adaptivelinear combiner for on-line tracking of power system harmonics,IEEE Trans. on Power Systems, 11 (4), 1996, 1730–1736. doi:10.1109/59.544635
  20. [20] L.L. Lai, W.L. Chan, C.T. Tse, & A.T.P. So, Real timefrequency and harmonic evaluation using artificial neural net-works, IEEE Trans. on Power Delivery, 14 (1), 1999, 52–57. doi:10.1109/61.736681
  21. [21] P.K. Dash, R.K. Jena, & M.M.A. Salama, Power qualitymonitoring using an integrated Fourier linear combiner andfuzzy expert system, Electric Power and Energy Systems,21 (2), 1999, 497–506. doi:10.1016/S0142-0615(99)00013-7
  22. [22] S. Santoso, E.J. Powers, & P. Hofmann, Power quality assess-ment via wavelet transform analysis, IEEE Trans. on PowerDelivery, 11 (2), 1996, 925–929. doi:10.1109/61.489353
  23. [23] L. Angrisani, P. Daponte, M.D. Apuzzo, & A. Testa, Ameasurement method based on wavelet transform for powerquality analysis, IEEE Trans. on Power Delivery, 13 (4), 1998,990–998. doi:10.1109/61.714415
  24. [24] J. Liu & P. Pillay, Wavelet analysis of power system tran-sients using scale-grams and multi-resolution analysis, ElectricMachines and Power Systems, 27, 1999, 1331–1341. doi:10.1080/073135699268614
  25. [25] A.M. Gaouda, M.M.A. Salama, M.R. Sultan, & A.Y. Chikhani,Power quality detection and classification using wavelet multi-resolution signal decomposition, IEEE Trans. on Power De-livery, 14 (4), 1999, 1469–1475. doi:10.1109/61.796242
  26. [26] A.M. Gaouda, M.M.A. Salama, M.R. Sultan, & A.Y. Chikhani,Application of multi-resolution signal decomposition for moni-toring short duration variations in distribution systems, IEEETrans. on Power Delivery, 15 (2), 2000, 478–485. doi:10.1109/61.852972
  27. [27] M. Karimi, H. Mokhtari, & M.R. Iravani, Wavelet based on-line disturbance detection for power quality applications, IEEETrans. on Power Delivery, 15 (4), 2000, 1212–1220. doi:10.1109/61.891505
  28. [28] A. Elmitwally, S. Faraghal, M. Kandil, S. Abdelkader, & M.Elkateb, Proposed wavelet neuro-fuzzy combined system forpower quality violations detection and diagnosis, IEE Proc.on Generation, Transmission & Distribution, 148 (1), 2001,15–20. doi:10.1049/ip-gtd:20010031
  29. [29] D. Borras, M. Castilla, N. Moreno, & J.C. Montano, Waveletand neural structure: A new tool for diagnostic of powersystem disturbances, IEEE Trans. on Industry Applications,37 (1), 2001, 184–191. doi:10.1109/28.903145
  30. [30] S.J. Huang, C.T. Hsieh, & C.L. Huang, Application of Morletwavelet to supervise power system disturbances, IEEE Trans.on Power Delivery, 14 (1), 1999, 253–261. doi:10.1109/61.736728
  31. [31] S.J. Huang, C.T. Hsieh, & C.L. Huang, Application of waveletsto classify power system disturbances, Electric Power SystemsResearch, 47 (2), 1998, 87–93. doi:10.1016/S0378-7796(98)00053-4
  32. [32] J.A. de la O, New family of digital filters for phasor computa-tion, IEEE Trans. on Power Delivery, 15 (1), 2000, 86–91. doi:10.1109/61.847233
  33. [33] O. Poisson, P. Rioual, & M. Meunier, Detection and measure-ment of power quality disturbances using wavelet transform,IEEE Trans. on Power Delivery, 15 (3), 2000, 1039–1044. doi:10.1109/61.871372
  34. [34] V.L. Pham & L.P. Wong, Wavelet transform based algorithmfor harmonic analysis of power system waveforms, IEE Proc.on Generation, Transmission & Distribution, 146 (3), 1999,249–254. doi:10.1049/ip-gtd:19990316
  35. [35] V.L. Pham & L.P. Wong, Anti-distortion method of wavelettransform filter banks and non-stationary power system wave-form harmonic analysis, IEE Proc. on Generation, Transmis-sion & Distribution, 148 (2), 2001, 117–122. doi:10.1049/ip-gtd:20010088
  36. [36] O. Poisson, P. Rioual, & M. Meunier, New signal progressingtools applied to power quality analysis, IEEE Trans. on PowerDelivery, 14 (2), 1999, 561–566. doi:10.1109/61.754104
  37. [37] Y.H. Gu, E. Styvaktakis, & M.H.J. Bollen, Analyzing powerdisturbances using the residuals of AR models, IEEE PowerEngineering Review, 20 (4), April 2000, 60–62.
  38. [38] S.J. Huang & C.T. Hsieh, Feasibility of fractal based methodsfor visualization of power system disturbances, Electrical Powerand Energy Systems, 23 (1), 2001, 31–36. doi:10.1016/S0142-0615(00)00036-3

Important Links: