DESIGN AND ANALYSIS OF THYRISTOR-CONTROLLED SERIES CAPACITOR AS STEADY STATE AND TRANSIENT VOLTAGE CONTROLLER IN RADIAL POWER SYSTEM

Fawzi A.L. Jowder

References

  1. [1] R.M. Mathur & R.K. Varma, Thyristor-based FACTS con-trollers for electrical transmission systems, First Edition (NewYork: IEEE Press, 2002).
  2. [2] L.A. Kilgore, L.C. Elliott, & E.R. Taylor, The prediction andcontrol of self-excited oscillations due to series capacitors inpower systems, IEEE Transactions on Power Apparatus andSystems, PAS-90, 1971, 1305–1311.
  3. [3] C.J. Bowler, D.N. Ewart, & C. Concordia, Self excited torsionalfrequency oscillations with series capacitors, IEEE Transac-tions on Power Apparatus and Systems, PAS-92 (5), 1973,1688–1695.
  4. [4] J.W. Balance & S. Goldberg, Subsynchronous resonance inseries compensated transmission lines, IEEE Transactions onPower Apparatus and Systems, PAS-92 (5), 1973, 1649–1658.
  5. [5] D.N. Walker, C.E.J. Bowler, R.L. Jackson, & D.A. Hodges,Results of subsynchronous resonance test at Mohave, IEEETransactions on Power Apparatus and Systems, PAS-94 (5),1975, 1878–1885.
  6. [6] N.G. Hingorani, A new scheme for subsynchronous resonancedamping of torsional oscillations and transient torque-Part I,IEEE Transactions on Power Apparatus and Systems, PAS-100 (4), 1981, 1825–1855.
  7. [7] J.J. Vithayathil, C.W. Taylor, M. Klinger, & W.A. Mittelstadt,Case studies of conventional and novel methods of reactivepower control of an AC transmission system, CIGRE paper38-02, 1988.
  8. [8] L.A.S. Pilotto, A. Biamco, W.F. Long, & A.A. Edris, Impact ofTCSC control methodologies on subsynchronous oscillations,IEEE Transactions on Power Delivery, 18(1), 2003, 243–252.
  9. [9] E. Larsen, C. Bowler, B. Damsky, & S. Nilson, Benefits of thyris-tor controlled series compensator, CIGRE paper 14/37/38-04,1992.
  10. [10] W. Zhu, R. Spee, R. Moler, G.C. Alexander, W.A.Mittlestadt, & D. Maratukulam, An EMTP study of SSRmitigation using the thyristor controlled series capacitor, IEEETransactions on Power Delivery, 10(3), 1995, 1479–1485.
  11. [11] J.F. Hauer, W.A. Mittlestadt, & R.J. Piwko, Modulation andSSR tests performed on the BPA 500kV TCSC unit at Slattsubstation, IEEE Transactions on Power Systems, 11(2), 1996,801–805.
  12. [12] X. Zhou & J. Liang, Overview of control schemes for the TCSCto enhance the stability of power systems, IEE ProceedingGeneration, Transmission and Distribution, 146(2), 1999,125–130.
  13. [13] S.A. Miske, Consideration for the applications of series capac-itors radial power distribution circuits, IEEE Transactions onPower Delivery, 16(2), 2001, 306–318.65
  14. [14] N.G. Hingorani & L. Gyugyi, Understanding FACTS: Conceptsand technology of flexible AC transmission systems (New York:IEEE Press, 2000).
  15. [15] F.A.L. Jowder, Steady state overvoltages of TCSC terminalsand their impact on degree of compensation and transmit-ted power of radial power system, International Journal ofEmerging Electric Power Systems, 1(1), 2006, Article 7.
  16. [16] R. Minguez, F. Milano, R. Zarate-Minano, & A.J. Conejo,Optimal network placement of SVC devices, IEEE Transactionson Power Systems, 22(4), 2001, 1851–1860.
  17. [17] S. Kincic, X.T. Wan, D.T. Mcgillis, A. Chandra, B.-T. Ooi,F.D. Galiana, & G. Joos, Voltage support by distributed staticVAr systems (SVS), IEEE Transactions on Power Delivery,20(2), 2005, 1541–1549.

Important Links:

Go Back