C. Urayai, F. Kong, and G.A.J. Amaratunga (UK)
Maximum power point (MPP), Maximum power point tracking (MPPT), perturb and observe algorithm (PO), incremental conductance algorithm (INC) and photovoltaic (PV).
A voltage sensing buck converter-based technique for maximum solar power delivery to a load is presented. While retaining the features and advantages of the incremental conductance algorithm, this technique is more desirable because of single sensor use. The technique operates by maximising power at the buck converter output instead of the input.