Modelisation, Optimisation and 4 Years Performance Study of a Photovoltaic System Connected to an Islander Electrical Grid

P. Poggi, M. Muselli, C. Cristofari, and G. Notton (France)

Keywords

PV Array, Small Gridconnected PV systems, Performance, modelisation

Abstract

This paper summarises 4 years of monitoring of a 850 Wp roof-mounted grid-connected system in our laboratory in Ajaccio. The system has been in operation since December 2000. The PV array consists of 10 BP585F modules and a SMA Sunny Boy 700 inverter. Climatic and solar radiation conditions al the site are reviewed, each component is modelled and the monthly performance of the system is assessed from a component point of view and from a global perspective.